ANSI/IEEE Standards Categories
ANSI/IEEE Standards Test Equipment, Systems & Solutions
-
Teseq NNB 51 Line Impedance Stabilization Network Dual-Line-V-LISN
SKU: 10154
Weight: 12 kg (26.5 pounds)Application/Test Type: Measure distortion signals on power mainsCurrent Rating: 16 Amps MaxDimensions: 27.0 cm x 41.8 cm x 27.5 cmFrequency Range: 9 kHz to 30 MHzImpedance: 50 ΩRF Connector: N female, 50 CISPR 16-1-2=Yes"DO-160F: YesCISPR 22: YesFCC: YesANSI C63.4: YesOhms"RF Input Voltage: 250 Volts maxStandards Met: CISPR 16-1-2, MIL-STD-461, FCC Part 15, ANSI C63.4$195.00RENTAL ONLY -
Com-Power LI-3P-216 LISN, 9 kHz to 30 MHz, 50/250 uH, 500 VAC
SKU: 11665
Weight: 27.5 lbs.Application/Test Type: Power Line Conducted Emissions TestsCurrent Rating: 16 AmperesDimensions: 19.3” x 13.9” x 2.3"Frequency Range: 9 kHz to 30 MHzInductors: 50 µHInsertion loss: less than 0.7 dBIsolation: more than 40 dBMains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power JackRF Connector: RF Measurement Port 50Ω - N-Type (female)Standards Met: ANSI C63.4, CISPR 16-1-2Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705V$5,795.00SHIPS IN 3-5 DAYS -
FCC-LISN-50-50-4-02 Line Impedance Stabilization Network
SKU: 12364-1
EUT Current Handling: 32 AmpsEUT Voltage Handling: 540V/260VApplications: CE Marking, Medical Devices, Industrial Machinery, Electronics & ITServices Available: ISO 17025 Calibration, Rentals, Leases, Purchases, Repairs, Eval/CharacterizationTest Standards: CISPR 16-1-2, VDE 0876, FCC part 15, MIL-STD 461, ISO 60601-1-2Inductance: 5 uHInquire for Availability -
Thermo Keytek E510A 10kV Surge Generator
SKU: sku-799
Standards Met: ANSI/IEEE C62.41 Cat. B and IEC 61000 4-5Phase synchronization: ±15° with optional coupler/decouplerPulse current (short circuit): 8/20µs, 0-5.05kA with 2 ohm effective source impedance, ±10%Pulse repetition: 1 shot/18 secondsPulse voltage (open circuit): 1.2/50µs, 0-10.1kV ±10% in 1 volt stepsRepetition time: Adjustable from 300ms to 5s; 1ms resolutionTypically In Stock -
Thermo Keytek ECAT Transient Generator System
SKU: 11321
Pulse current (short circuit): Selectable at 200A max. or 500A max., when the open-circuit voltage is set to 6.0kV.Pulse repetition: 1 shot/9 secondsPulse voltage (open circuit): 200V - 6.6kV ± 10%Ringwave 0.5 μs/100 kHz: Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41Standards Met: ANSI/IEEE C62.41 Cat. A and B, and various UL standards, including UL 864In Stock -
3ctest CWS 800 8kV Surge Combination Wave Simulator for IEC/EN 61000-4-5 up to 8 kV
SKU: sku-797
Weight: Approx 30 kg (66 lbs)Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5Coupling: Single Phase Built in, 16A, 250VAC, 120VDCDimensions: 19 inch/6uImpedance: 2 OhmMains & EUT Connections: 4mm banana plugPhase synchronization: 0°-360°, 1°step or randomPolarity: Positive, Negative, AlternatePulse current (short circuit): 0.1kA-3kA ±10%Pulse repetition: 1-999Pulse voltage (open circuit): 0.2kV - 8kV ±10%Standards Met: IEC 61000-4-5, UL1449 and more -
ETS-Lindgren 3142D Biconilog Antenna, 26 - 6000 MHz
SKU: 2841
Standards: IEC 61000-4-3,FMC 1278, GMW3097Antenna Factor (1 Meter): -23 to 8 dBiApplication/Test Type: RF EMC immunity testingConnector: N type femaleDimensions: 52.7 in. (133.9 cm) x 66.2 in (168.1 cm) x 30 in (76.2 cm)Frequency Range: 25 MHz - 6 GHzGain: 8 dBiMaximum Continuous Power: 500 WattsInquire For Lead Time -
Rent Com-Power LI-3P-132 150kHz to 30MHz Three-Phase Line Impedance Stabilization Network
SKU: 11124
Weight: 27.5 lbs.Application/Test Type: Power Line Conducted Emissions TestsCurrent Rating: 32 AmperesDimensions: 19.3” x 13.9” x 2.3"Frequency Range: 150 kHz to 30 MHzInductors: 50 µHInsertion loss: less than 0.7 dBIsolation: more than 40 dBMains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power JackRF Connector: RF Measurement Port 50Ω - N-Type (female)Standards Met: ANSI C63.4, CISPR 16-1-2Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705VInquire for Availability -
Radiated Emissions Testing Equipment for FCC, MIL and More
SKU: sku-1164
Generic Standards: IEC 61000-6-3, IEC 61000-6-4 -
Com-Power LI-3P-132 150kHz to 30MHz Three-Phase Line Impedance Stabilization Network
SKU: sku-598
Weight: 30 lbs.Application/Test Type: Power Line Conducted Emissions TestsCurrent Rating: 32 AmperesFrequency Range: 150 kHz to 30 MHzInductors: 50 µHInsertion loss: less than 0.7 dBIsolation: more than 40 dBMains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power JackRF Connector: RF Measurement Port 50Ω - N-Type (female)Standards Met: ANSI C63.4, CISPR 16-1-2Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705V$6,495.00 -
PMM L3-64 3-Phase, 64 Amp LISN for FCC Part 15
SKU: sku-57
Weight: 50 kg (110 pounds)Application/Test Type: Ancillary device intended for repeatable and accurate measurement of the disturbance voltage that an EUT (Equipment Under Test) may inject into the power line or mains.Current Rating: 63 Amps MaxDimensions: 465 x 450 x 740 mm (18 x 17.7 x 29 inches)Frequency Range: 9 kHz to 30 MHzInductors: 50 Ω // [5 Ω + 50 µH] with 250 µH chokeMains & EUT Connections: 63 A IEC connectorRF Connector: BNC (f)Standards Met: CISPR 16-1-2; VDE 0876; FCC part 15; MIL-STD 461FVoltage Rating: 230 Volts AC, 325 Volts DC (Line to Power Earth and Neutral to Power Earth); 400 Volts AC, 565 Volts DC (line to line and line to neutral)CISPR 16-1-2: YesDO-160F: YesCISPR 22: YesFCC: YesANSI C63.4: Yes -
3ctest CWS 1000N 10kV Surge Generator for IEC/EN 61000-4-5
SKU: sku-798
Weight: Approx 44 kg (97 lbs)Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5Dimensions: 19 inch/6uImpedance: 2 OhmPhase synchronization: 0°-360°, 1°step or randomPolarity: Positive, Negative, AlternatePulse current (short circuit): 0.1kA-5kA ±10%Pulse voltage (open circuit): 0.2kV - 10kV ±10%Standards Met: IEC 61000-4-5