Com-Power CDN's

(Showing 7 of 19)

Com-Power CDNs (Coupling/Decoupling Networks) are primarily used for RF conducted immunity testing per IEC 61000-4-6, which is one of the EMC (electromagnetic compatibility) phenomenon tests typically required for “CE-mark” compliance testing of commercial products.

The EMC Shop stocks calibrated CDN's for rental or sale.

Show 12

Com-Power CDN's Categories

Com-Power CDN's Test Equipment, Systems & Solutions

  • Com-Power CDN-T8E Unshielded/Unscreened Cable with 4 Balanced Conductor Pairs

    SKU: sku-94

    Weight: 5 lbs. 2.3 kg
    Application/Test Type: Four unscreened, balanced pair
    Common Mode Impedance: 150 kHz - 26 MHz: 150Ω ± 20Ω 26 MHz - 80 MHz: 150Ω + 60Ω / – 45Ω 80 MHz - 230 MHz: 150Ω + 60Ω / – 60Ω
    Current Rating: 1.5 Amps (Max)
    Decoupling of Common Mode Disturbance: 150 KHz ≥ 45dB (RF/AE) 500 KHz ≥ 50dB (RF/AE) 230 MHz ≥ 50dB (RF/AE)
    Dimensions: 8.5 x 4.5 x 3.5 inches 21.5 x 11.4 x 8.8 cm
    Frequency Range: 150 kHz to 230 MHz
    Mains & EUT Connections: RJ45 (AE & EUT)
    RF Connector: 50 Ω BNC (Female)
    RF Input Voltage: 40 V (Max)
    Standards Met: IEC / EN 61000-4-6
    Voltage Division Factor: 9.5 dB +4 / -1
    Voltage Rating: 124 V AC / 125 V DC (Line to Ground)
  • Com-Power CDN-M425E 3-Phase + Earth Coupling Decoupling Network

    SKU: sku-90

    Weight: 5 lbs. 2.3 kg
    Application/Test Type: Four conductor power cable
    Common Mode Impedance: 150 kHz - 26 MHz: 150Ω ± 20Ω 26 MHz - 80 MHz: 150Ω + 60Ω / – 45Ω 80 MHz - 230 MHz: 150Ω + 60Ω / – 60Ω
    Current Rating: 25 Amps AC / 17 Amps DC (Max)
    Decoupling of Common Mode Disturbance: ≥ 40dB (EUT/AE)
    Dimensions: 6 x 6 x 13 inches 15.2 x 15.2 x 33 cm
    Frequency Range: 150 kHz to 230 MHz
    Mains & EUT Connections: 4 mm shrouded banana sockets
    RF Connector: 50 Ω BNC (Female)
    RF Input Voltage: 40 V (Max)
    Standards Met: IEC / EN 61000-4-6
    Voltage Division Factor: 9.5 dB +4 / -1
    Voltage Rating: 250 V AC / 350 V DC (Line to Ground)
  • Com-Power CDN-M325E 150 kHz - 230 MHz 3-Line RF Coupling Decoupling Network

    SKU: 4845

    EMC Standard: IEC/EN 61000-4-6
    Application/Test Type: Three conductor power cable
    Associated Equipment: RF Conducted Immunity Test Systems
    Current Rating: 25 Amps AC / 17 Amps DC (Max)
    Decoupling of Common Mode Disturbance: ≥ 40dB (EUT/AE)
    Dimensions: 6 x 6 x 13 inches 15.2 x 15.2 x 33 cm
    Frequency Range: 150 kHz to 230 MHz
    Mains & EUT Connections: 4 mm shrouded banana sockets
    RF Connector: 50 Ω BNC (Female)
    RF Input Voltage: 40 V (Max)
    Standards Met: IEC 61000-4-6
    Voltage Division Factor: 9.5 dB +4 / -1
    Voltage Rating: 250 V AC / 350 V DC (Line to Ground)
    Typically In Stock
  • Com-Power CDN-M225E Coupling Decoupling Network for Unscreened Power Supply Lines

    SKU: sku-54

    Weight: 5 lbs. 2.3 kg
    Application/Test Type: two conductor power cable
    Common Mode Impedance: 150 kHz - 26 MHz: 150Ω ± 20Ω 26 MHz - 80 MHz: 150Ω + 60Ω / – 45Ω 80 MHz - 230 MHz: 150Ω + 60Ω / – 60Ω
    Current Rating: 25 Amps AC / 17 Amps DC (Max)
    Decoupling of Common Mode Disturbance: ≥ 40dB (EUT/AE)
    Dimensions: 6 x 6 x 13 inches 15.2 x 15.2 x 33 cm
    Frequency Range: 150 kHz to 230 MHz
    Mains & EUT Connections: 4 mm shrouded banana sockets
    RF Connector: 50 Ω BNC (Female)
    RF Input Voltage: 40 V (Max)
    Standards Met: IEC / EN 61000-4-6
    Voltage Division Factor: 9.5 dB +4 / -1
    Voltage Rating: 250 V AC / 350 V DC (Line to Ground)
  • Com-Power CDN-M525E 5-Line Coupling Decoupling Network for Unscreened Power Lines

    SKU: 10475

    Current Rating: 25 Amps AC / 17 Amps DC (Max)
    Decoupling of Common Mode Disturbance: ≥ 40dB (EUT/AE)
    Frequency Range: 150 kHz to 230 MHz
    Mains & EUT Connections: 4 mm shrouded banana sockets
    RF Connector: 50 Ω BNC (Female)
    RF Input Voltage: 40 V (Max)
    Standards Met: IEC / EN 61000-4-6
    Voltage Division Factor: 9.5 dB +4 / -1
    Voltage Rating: 250 V AC / 350 V DC (Line to Ground)
    $589.00 - $3,275.00
    In Stock