Test Equipment, Systems & Solutions

  • Teseq PCJ 9201B Probe Calibration Jig

    SKU: 11132

    Weight: 4.5 Kgs (10 lbs)
    Dimensions: 26.0 cm x 18.1 cm x 15.0 cm (Max Probe Diameter: 11.5 cm; Min Probe Window Diameter: 1.6 cm; Max: 6.7 cm)
    Frequency Range: DC to 400 MHz
    Impedance: 50 Ohms
    RF Connector: N-type
    Standards Met: ISO 11452-4, RTCA/DO-160 section 20, MIL-STD-461 and IEC/EN 61000-4-6
    VSWR: up to 1 MHz ≤ 1.10:1; 10 MHz ≤ 1.14:1; 30 MHz ≤ 1.22:1; 100 MHz ≤ 1.50:1; 200 MHz ≤ 2.00:1; 300 MHz ≤ 2.75:1; 400 MHz ≤ 3.50:1
  • Teseq DPA 3000 Biconical Dipole Antenna 800 to 2800 MHz

    SKU: sku-125

    Impedance: 50 Ohms
    Weight: 180 grams
    Antenna Factor (1 Meter): 30 dB/m to 38 dB/m (0.8 GHz to 2.5 GHz)
    Antennas: Dipole Antennas
    Connector: N female
    Dimensions: (L x W x H): 155 mm x 155 mm x 75 mm
    Frequency Range: 800 MHz to 2800 MHz
    Gain: -2.0 dB to +1.5 dB (0.8 GHz to 2.5 GHz)
    Impedance-2: 50 Ω, nominal
    Standards Met: CISPR 13, CISPR 14-1, CISPR 16-1-4, CISPR 16-2-3, CISPR 22, CISPR 32, EN 61000-6-3, EN 61000-6-4
    VSWR: Under 2.5:1 (1.0 GHz to 2.5 GHz)
  • Teseq (Schaffner) KEMZ 801A EM Clamp Conform with IEC/EN 61000-4-6

    SKU: sku-119

    Weight: approx. 7 kg
    Application/Test Type: Injects the disturbance signal through a combination of inductive and capacitive coupling
    Clamp factor (CF): Max (0.15 to 400 MHz): 4 dB (50 Ω system) and 13.5 dB (150 Ω system)
    Connector: N-type female
    Dimensions: 647 mm x 130 mm x 105 mm
    Frequency Range: 10 kHz to 1000 MHz
    Impedance: 50 Ohms
    Max. Cable Diameter: 20 mm
    Maximum Continuous Power: 0.01 to 100 MHz: 100 W for 15 min; 100 to 230 MHz: 100 W for 3 min; 230 to 1000 MHz: 50 W for 3 min
    Standards Met: IEC/EN 61000-4-6; CISPR 24; EN 61000-6-1; EN 61000-6-2; IEC 60533; IEC 60601-1-2; IEC 61326
  • Teseq INA 6501 Manual Step Transformer for AC Dips & Interruptions

    SKU: sku-116

    Accuracy: ±5%
    Input voltage UIN: 0 to 250 VAC, 50/60 Hz
    Output voltage UVAR: 4 steps: 0% - 40% - 70% - 80% of UIN
    Voltage change with load: 00% output, 0 to 16 A less than 5%; 80% output, 0 to 20 A less than 5%; 70% output, 0 to 23 A less than 5%; 40% output, 0 to 40 A less than 5%
    $2,060.00
  • EM Test (Lüthi) M2 Coupling/Decoupling Network M-Type CDN for 2 Mains AC/DC Power Lines

    SKU: sku-104

    Application/Test Type: Coupling/decoupling networks for Conducted immunity, 2 mains AC/DC power supply lines
    Current Rating: 16,32,50,75,100 Amps (Max)
    Frequency Range: 150 kHz to 230 MHz (10 kHz - 80 MHz Optional)
    Mains & EUT Connections: AE: IEC 60320/C14 connector EUT: 4mm safety lab connectors
    RF Input Voltage: 30 V (Max)
    Standards Met: IEC / EN 61000-4-6
    Voltage Rating: 1,000 Volts AC / 1,000 Volts DC
  • EM Test (Lüthi) M1 CDN for Earth Conductor 250V AC / 1,000V DC

    SKU: sku-103

    Application/Test Type: Coupling/decoupling networks for Conducted immunity, mains AC power supply lines
    Current Rating: 16 Amps (Max)
    Frequency Range: 150 kHz to 230 MHz
    Mains & EUT Connections: 4mm safety lab connector
    RF Input Voltage: 30 V (Max)
    Standards Met: IEC / EN 61000-4-6
    Voltage Rating: 250 V AC / 1,000 V DC