Categories
Test Equipment, Systems & Solutions
-
Rent AH Systems BCP-611 10 KHz – 150 MHz Broadband Current Probe
SKU: sku-257
Weight: 1.4 Lbs (650 grams)Aperture: 1.25" (32 mm)Application/Test Type: Measure currents on 50 Hz, 60 Hz and 400 Hz powerlines without making direct contact with the source conductor or metallic surfaceCurrent Rating: 400 Amps (5,000 Peak) MaximumFrequency Range: 10 KHz to 150 MHzRF Connector: N-Type(female)Standards Met: IEC 61000-4-16, IEC 61000-4-19 Annex C, SAE J1113-2, ISO 11452-8, DO 160D/E Section 18 and MIL-STD-461 D/E CS101, CS109 and RS101.Transfer Impedance: -63 to -28 dBΩ -
EM Test CWS 500N4 Common-Mode Disturbance Simulator for IEC 61000-4-16 & IEC 61000-4-19
SKU: sku-254
Weight: Approx. 30kgDimensions: 555mm x 448mm x 286mmFrequency Range: 10Hz to 165kHzMax input power: 600 WattsOutput: For output characteristics reference data sheetSupply Voltage: 115V - 230V +10/-15%, 50/60Hz -
EM Test CWS 500N2.2 BCI Test System
SKU: sku-252
Test Capabilities: RF Conducted ImmunityStandards Met: MIL STD 461 CS 114, DO-160 CS TestApplications: Vehicle, Military and Aerospace, BCI TestingBCI Test Levels (w/ built-in amplifier): 400mA/114 dBµAFrequency Range (w/ built-in amplifier): 9 kHz - 400 MHzTypically In Stock -
AH Systems PAM-0204 Preamplifier, 20 MHz - 4 GHz, 24 dB
SKU: 10249
Weight: 1.1 lbs. / 0.5 kgApplication/Test Type: Improve overall system sensitivity for field measurements.Connector: N(f) to N(f)Dimensions: 2.5" x 3.75" x 6.25" (63mm x 95mm x 158mm)Frequency Range: 20 MHz - 4 GHzGain: 26 dB typical (22 dB minimum)Input: 100/220 VAC regulated P/S output: 12 VDC 170 mAVSWR: 2.0:1 Input; 1.7:1 Output$550.00Typically In Stock -
PMM (Narda) LP-03 Log Periodic Antenna, 800 MHz - 6 GHz
SKU: sku-238
Weight: 0.25 kgs (0.6 LB's)Antenna Factor (1 Meter): 23 / 42 dB typicalAntennas: Log Periodic AntennasApplication/Test Type: Radiated emissions and immunityConnector: Type-N(m) or Type-N(f)Dimensions: 18.7 cm x 32.5 cm x 8.1 cmFrequency Range: 800 MHz to 6 GHzGain: 3.5 to 6.5 dBi typicalImpedance: 50 Ω nominalMaximum Continuous Power: 75 WattsMounting Base: Tripod adapter, suppliedStandards Met: IEC 61000-4-6, MIL-STD-461F, DO-160VSWR: Less than 1.7:1 typical -
AH Systems SAC-210 RF Cable Up to 5 GHz, BNC(m) to BNC(m)
SKU: sku-234
RF Connector: BNC(m) to BNC(m), RG-58 -
EM Test (Lüthi) CDN T-Type Coupling/Decoupling Network for Unshielded Lines
SKU: sku-232
Application/Test Type: EMC testing for unscreened data communication/telecom lines (Power over Ethernet, 1100BaseT4, 100Base VG-AnyLan, 1000BaseT, Token ring, ISDN, 10BaseT, 100BaseTX, ATM, FDDI, TP-PMDCurrent Rating: 1.5 Amps (3/5 Amp models available)Frequency Range: 150 kHz to 230 MHz (limited to 80 MHz on 3/5 Amp models)Mains & EUT Connections: Banana, XLR, RJ45, RJ11RF Connector: BNC, 50 ΩRF Input Voltage: 30 Volts MaxStandards Met: IEC 61000-4-6Voltage Rating: AC max. voltage (line to ground): 63 Volts DC max. voltage (line to ground): 100 Volts Test voltage: 200 VDC, 2 s -
EM Test (Lüthi) AF-Type Coupling/Decoupling Network for Unscreened/Unsymmetrical Lines
SKU: sku-231
Application/Test Type: Immunity test to conducted disturbances, induced by radio-frequency fields according to the standardsCurrent Rating: 1.5 Amps (Optional 3 Amps)Frequency Range: 10 kHz to 80 MHz or 150 kHz to 230/300 MHzMains & EUT Connections: 4 mm banana or D-Sub 15/25 pinsRF Connector: BNC 50 ΩRF Input Voltage: 30 Volts MaxStandards Met: IEC 61000-4-6, CISPR 15, IEC/EN 60945, EN 55015Voltage Rating: AC max. voltage (line to ground): 63V - 250V; DC max. voltage (line to ground): 100V - 250V; -
Teseq CDN AF Series Coupling/Decoupling Network for Unscreened/Unbalanced Lines
SKU: sku-230
Weight: 1.5 kg (3.3 lbs)Application/Test Type: Coupling / decoupling network (CDN) used for all unscreened, unbalanced lines, carrying low currentCommon Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 2300 MHz: 150 Ω +60 Ω / -45 Ω; 230 MHz to 300 MHz 1): 150 Ω +60 Ω / -60 ΩCurrent Rating: 200 mA to 4 Amps (refer to data sheet for exact model specifications)Decoupling of Common Mode Disturbance: 10 kHz: Over 10 dB:150 kHz: Over 35 dB: 26 MHz: Over 45 dB: 80 MHz: Over 25 dB;150 kHz: Over 30 dB: 1.5 MHz: Over 60 dB: 30 MHz: Over 50 dB: 230 MHz: Under 30 dB (refer to data sheet for some exceptions)Dimensions: 4 x 4 x 9.5 inches (10 cm x 10 cm x 24 cm); (CDN HDMI and CDN S752A: 28.8 cm 11 inches)Frequency Range: 10 kHz to 80 MHz or 150 kHz to 230/300 MHzMains & EUT Connections: 4 mm banana or D-Sub 25 pinsRF Connector: BNC 50 ΩRF Input Voltage: 30 Volts MaxStandards Met: IEC 61000-4-6, CISPR 15Voltage Division Factor: 150 kHz to 80 MHz: 9.5 dB ±1 dB, 10 dB ±1 dB for CDN A501, A701, A801; 80 MHz to 300 MHz 1): 9.5 dB +3 dB / -2 dB 10 dB +3 dB / -2 dB for CDN A501, A701, A801; All other models 10 dB ±1 dBVoltage Rating: AC max. voltage (line to ground): 63V - 160V; DC max. voltage (line to ground): 100V - 250V; Test voltage: 250 V - 400 V DC, 2 sec (refer to data sheet for exact model specifications) -
Teseq CDN S Series Coupling Network for Screened or Coaxial Cables
SKU: 4255
Application/Test Type: Coupling / decoupling network (CDN) for screened data/telcom lines or coaxial cablesCommon Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 250 mA (CDN ST08 1 Amp)Decoupling of Common Mode Disturbance: 150 kHz: Over 60 dB; 1.5 MHz: Over 60 dB; 30 MHz: Over 50 dB; 230 MHz: Over 40 dB (refer to data sheet for some exceptions)Frequency Range: 10 kHz to 80 MHz or 150 kHz to 230 MHzMains & EUT Connections: BNC 50 Ω, N 50 Ω, BNC 75 Ω, N 75 Ω, XLR 3 pins, DIN 5 pins, RJ45, D-Sub 9 pins, D-Sub 15 pins, D-Sub 25 pins, HDMI (refer to data sheet for exact model specifications)RF Connector: BNC 50 ΩRF Input Voltage: 20 Volts MaxStandards Met: IEC 61000-4-6, CISPR 22, IEC 60601-1-2Voltage Division Factor: 9.5 dB to 10 dB ±1 dB (refer to data sheet for some exceptions)Voltage Rating: AC max. voltage (line to ground): 100 V - 250V; DC max. voltage (line to ground): 150 V - 400 V; Test voltage: 200 V - 750 V DC, 2 sec (refer to data sheet for exact model specifications)$710.00 -
Teseq CDN T Series Coupling Network for Unscreened Communication/Data Lines
SKU: sku-228
Weight: 0.5 kg (1.1 LB.'s)Application/Test Type: EMC testing for unscreened data communication/telecom lines (Power over Ethernet, 1100BaseT4, 100Base VG-AnyLan, 1000BaseT, Token ring, ISDN, 10BaseT, 100BaseTX, ATM, FDDI, TP-PMDCommon Mode Impedance: 10 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 80 MHz: 150 Ω +60 Ω / -45 Ω; 80 MHz to (230) 300 MHz: 150 Ω +60 Ω / -60 ΩCurrent Rating: 400 mA (line), 800 mA (pair)Decoupling of Common Mode Disturbance: 10 kHz: Over 20 dB; 1.5 MHz / 30 MHz: Over 55 dB; 80 MHz: Over 45 dB; 230 MHz: Over 35 dB;Dimensions: 4.1 x 2.5 x 4.3 inches (10.5 cm x 6.5 cm x 11.0 cm)Frequency Range: 150 kHz to 80 MHz (Optional 10 kHz - 230/300 MHz)Mains & EUT Connections: D-Sub adapter to RJ45 / RJ11 (1 mm banana on certain 10 kHz models)RF Connector: BNC, 50 ΩRF Input Voltage: 20 Volts MaxStandards Met: IEC 61000-4-6Voltage Division Factor: 9.5 dB ±1 dB (10 kHz to 230 MHz: 10 dB ±1 dB)Voltage Rating: AC max. voltage (line to ground): 63 Volts DC max. voltage (line to ground): 100 Volts Test voltage: 200 VDC, 2 s -
Teseq CDN M5 5-Line Coupling Network for AC Power Lines, 16-32 Amps
SKU: sku-227
Weight: 6.5 kg (14.3 LB.'s)Application/Test Type: 5 mains AC power lines emissions testing up to 32 Amps (3L+N+PE)Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 32 Amps MaximumDecoupling of Common Mode Disturbance: Greater than 30 dBDimensions: 6.3 x 6.3 x 20 inches (16.0 cm x 16.0 cm x 50.0 cm)Frequency Range: 150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)Insertion Loss: Greater than 0.1 dBMains & EUT Connections: 4 mm, safety (Optional IEC 320 16A)RF Connector: BNC, 50 ΩRF Input Voltage: Less than 30 VStandards Met: IEC 61000-4-6Voltage Division Factor: 10 dB +3 dB / -1 dBVoltage Rating: AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec