Test Application Categories
Test Application
-
Haefely AXOS5 Surge/EFT/Burst Impulse Generator up to 5 kV
SKU: 10180
Applications: Conducted Immunity Testing, CE Marking, Medical DevicesStandards Met: IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-11Max EUT AC Voltage (W/ Built In CDN): 264 VoltsMax EUT AC Current (W/ Built In CDN): 16 AmpsEFT/Burst Pulse Output Capability: 5.0 kV$975.00 - $1,795.00Typically In Stock -
Teseq LNA 6018 Low Noise Amplifier 1 GHz to 18 GHz
SKU: sku-83
Weight: 220 grams (0.3 Lbs)Application/Test Type: Significantly increase the sensitivity of virtually all spectrum analyzers and other RF measuring instrumentsConnector: IN: SMA female 50 Ohms; OUT: SMA male 50 OhmsDimensions: 39 mm x 88 mm x 36 mmFrequency Range: 1 GHz - 18 GHz -
Teseq LNA 6900 Low Noise Amplifier 9 kHz to 2 GHz
SKU: sku-81
Weight: 0.27 Lb's (127 grams)Connector: N-type 50 OhmsDimensions: 28 mm x 95 mm x 27 mmFrequency Range: 1 MHz to 3 GHz (nominal range); 200 kHz to 4 GHz (utilizable range)Gain: 12.5 dB (±0.3 dB flatness) -
Teseq MD 103 1 Ohm Current ESD Pulse Target
SKU: 10035
Resistance: 1.00 Ohm - ± 1% 1.00 Ohm when match with 50 Ohm loadFrequency Range: DC - 4 GHzGrounding Plane & Cal Setup: Avaialble at ESDGuns.com$450.00 - $2,950.00Typically In Stock -
PMM 9010
SKU: 11026
Frequency Range: 10 Hz - 30 MHzApplications: Conducted EmissionsTest Standards: CISPR 14, CISPR 16-1-1$2,750.00 - $5,500.00In Stock -
Teseq NSG 438 30kV ESD Simulator Gun
SKU: 10121
Standards Met: IEC 61000-4-2, ISO 10605Need to test now?: ESD Gun Rentals Ship Same DayVoltage Range: 200 V to 30k V (in 100 V steps)Polarity: Positive / negative / automatic changePre-Programmed IEC Levels: Yes$475.00 - $1,190.00IN STOCK -
Magnetic Field Immunity Test System per IEC 61000-4-39
SKU: 88641
- Coil sets with matching network, stand and corresponding cables for different frequency ranges
- Utilized with the RFCI-MIL and preamplifier as a complete test set for IEC 60601-1-2
- System achieved radiated and magnetic field immunity tests according to IEC 61000-4-39
- Software for impedance matching between amplifier and loop sensor
- Rentals Ship Same Day
Typically In Stock -
HGLP6G Dual Stacked Log Periodic Antenna
SKU: 31099
Frequency Range: 1 GHz – 6 GHzMaw RF Input Power: 350 WattsIsotropic Gain: 9 dBi ± 2.3 dBConnector Type: N (f)VSWR: 2:1 typicalIn Stock -
Wavecontrol WP10M E & H Field Probe, 1 Hz - 10 MHz
SKU: 15236
Frequency Range: 1 Hz – 10 MHzMeasurement Range (Magnetic Field): 100 nT - 4.7 mT (500 Hz – 10 MHz) - 47 mT @ 50 HzMeasurement Range (Electric Field): 2 V/m - 47 kV/m (80 kHz - 10 MHz) - 100 kV/m up to 80 kHzPre-Programmed Standards/Limits: EU Directive 2013/35/EU, IEEE, ICNIRP, BGV B11Inquire for Availability -
Wavecontrol WPf40 Broadband E-Field Probe, 1 MHz - 40 GHz
SKU: 2027
Field Strength Range: 1 - 1,000 V/mApplication/Test Type: Monitoring electric field strengthsVideos: Menu Run-ThroughFrequency Range: 1 MHz - 40 GHzTypically In Stock -
3ctest EDS 10IC HBM/MM Electrostatic Discharge Simulator
SKU: 6980
Output Voltage: HBM 5~8000V 5%+5V; MM 5~1000V 5%+5VPolarity: Positive, Negative, AlternateTime Interval: 0.1 - 10s adjustableTrigger Mode: Automatic, single or external triggerPower Supply: AC100 ~ 240V +/-10% 50/60HzIN STOCK -
Langer MFA 01 Micro Probe Set 1 MHz to 6 GHz
SKU: 30012
Frequency Range: 1 MHz to 6 GHzResolution: 200 µmApplications: Conducted Emissions, Radiated EmissionsTest Standards: CISPR, MIL-STD-461, FCC$349.00 - $3,819.00Typically In Stock