Categories
Test Equipment, Systems & Solutions
-
Teseq (Schaffner) NSG 2050 System PNW 2050 w/ CDN 131/133
SKU: 11050
Standards Met: IEC/EN 61000-4-5, IEC/ISO 60601-1-2Applications: EMC Surge, CE Marking, Surge ImmunityMax EUT AC Voltage (W/ Built In CDN): 690 VoltsMax EUT AC Current (W/ Built In CDN): 32 AmpsMax EUT DC Voltage (W/ Built In CDN): 270 VoltsMax EUT DC Current (W/ Built In CDN): 16 AmpsCombination/Wave Surge Output Capability: 4.4 kVExternal Coupling: Data Lines (Surge), 3PH EUTWarranty: 100 DaysCondition (5-10 Scale): 8Equipment Group: Combination Wave GeneratorsTest Setup: Surge Immunity Test, Setup, Equipment$5,975.001 System Left -
Amplifier Research 50W1000B 1 MHz - 1 GHz RF Power Amplifier
SKU: 10922
Frequency Range: 1 MHz - 1 GHzOutput Power: 50 WFlatness: ±1.0 dB typical, ±1.5 dB maximumGain: 47 dB minimum (at max setting)Imput Impedance: 50 ohms, VSWR 2.0:1 maximumOutput Impedance: 50 ohms nominal$695.00In Stock -
Thermo Keytek E510A 10kV Surge Generator
SKU: 10799
Standards Met: ANSI/IEEE C62.41 Cat. B and IEC 61000 4-5Phase synchronization: ±15° with optional coupler/decouplerPulse current (short circuit): 8/20µs, 0-5.05kA with 2 ohm effective source impedance, ±10%Pulse repetition: 1 shot/18 secondsPulse voltage (open circuit): 1.2/50µs, 0-10.1kV ±10% in 1 volt stepsRepetition time: Adjustable from 300ms to 5s; 1ms resolutionTypically In Stock -
AH Systems TDS-535 Tuned Dipole Set, 25 MHz to 1 GHz, Receive and Transmit
SKU: 10742
Weight: 19 lbs.Antennas: Dipole AntennasApplication/Test Type: precise EMI measurementsConnector: N-type (female)Dimensions: Antenna Case: 28” x 23” x 7”Frequency Range: 25 MHz - 1 GHzGain: Varies with ModelImpedance: 50 ohmInquire for Availability -
Amplifier Research 50T4G18, 50 Watts CW, 4.2–18GHz, (TWT) Microwave Amplifier
SKU: sku-717
Weight: 70 lbs, 32 kgDimensions: 19.8 x 6.5 x 27 in., 50.3 x 16.5 x 68.6 cm.Flatness: ±10 dB maximum, 4.2 - 18 GHzFrequency Range: 4.2–18GHzGain: GAIN (at maximum setting) ......47 dB minimum GAIN ADJUSTMENT (continuous range)......35 dB minimumImpedance: 50 ohmsInput: 99-260 VACOutput: POWER (fundamental), CW, @ OUTPUT CONNECTOR Nominal .60 watts Minimum..50 watts Linear @ 1dB Compression..10 watts minimumRF Connector: Type N femaleRF Input Voltage: 1.0 milliwatt maximum for rated output -
EM Test ACC Capacitive Coupling Clamp for ISO 7637 Automotive Testing
SKU: sku-635
Weight: 11.5 kgApplication/Test Type: Electrical Fast Transients for automotive applicationsCable Diameter: up to 40 mm (1.57 in)Coupling Length: 1 m (39.4 in)Dimensions: 1250 mm x 300 mm x 93 mm, L x W x HRF Connector: High voltage connector,coaxial. GND connection 4 mm plug, bananaStandards Met: ISO 7637Voltage Rating: up to 1.0 kVInquire for availability -
3ctest CCC100 EFT/Burst Coupling Clamp for IEC/EN 61000-4-4
SKU: 10621
Application/Test Type: Electrical Fast Transients on Data Lines (EFT Burst)Cable Diameter: up to 40 mm (1.57 in)Coupling Length: 1 m (39.4 in)Dimensions: 1040x140x110mmEFT Coupling Clamps: as per IEC 61000-4-4RF Connector: High voltage connector,coaxial. GND connection 4 mm plug, bananaStandards Met: IEC/EN 61000-4-4Voltage Rating: up to 5.5kv4 to 6 Weeks -
Haefely PSURGE 4010 Combination Wave Generator
SKU: 10574
Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5Coupling: Internal Single Phase/16 Amps at 264 VAC and 110 VDC -(expandable to 3-Phase with external module); 18uF and 9uF+10 Ω acc. to IEC 61000-4-5Polarity: positive, negative, alternatingPulse current (short circuit): 100 Amps to 2.1 kAPulse repetition: up to 12 per minutePulse voltage (open circuit): 200 Volts to 4.2 kVStandards Met: IEC 61000-4-5, EN 61000-6-1, EN 61000-6-2Industries: CE Marking, Medical Devices, Industrial Machinery, Electronics & ITApplications: Immunity to Electrical Surges (Test Setup)Typically In Stock -
Com-Power AM-741R Active Monopole Antenna with RAI-100, 9 kHz - 60 MHz
SKU: AM-741R, RAI-100
Weight: 9.5 lbs. [4.3 kg]Antenna Factor (1 Meter): ±0.5 dBAntennas: Monopole AntennasApplication/Test Type: radiated emissions measurements, typically below 30 MHz.Connector: BNC (female)Frequency Range: 9 kHz to 30 MHz (useable to 60 MHz)Gain: See Image ThumbnailImpedance: 50 OhmsMounting Base: 1/4" 20 threadStandards Met: Mil-STD 461,DO-160$299.99Typically In Stock -
Com-Power CGC-255E Comb Generator 50 kHz - 400 MHz in 50 kHz/250 kHz steps
SKU: 11431
Weight: 1 lbs / 0.5 kgAC Power Adapter: 6 VDC, 500 mA / 110VAC 60 Hz or 230 VAC 50 HzApplication/Test Type: Reference Signal Source for LISN verificationBattery: 6V NiMH, 1 AhDimensions: 5 x 2.2 x 2.2 inches / 13.2 x 5.9 x 5.9 cmFrequency Range: 50 kHz to 400 MHz in 50 kHz or 250 kHz stepsMains & EUT Connections: LISN Interface Plug NEMA 15-P typeOperation Time: 18 Hours Typical With Fully Charged BatteryInquire for Availability -
Haefely AXOS 8 7kV Surge & EFT Generator
SKU: 10405
Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & VariationsTransient EMC Standards: IEC/EN 61000-4-4, IEC/EN 61000-4-5Power Fail EMC Standards: IEC/EN 61000-4-11, IEC/EN 61000-4-29Max EUT AC Voltage (w/ Built in CDN): 264 VoltsMax EUT AC Current (w/ Built in CDN): 16 AmpsPeak inrush current capability: 500 A (at 230 V)External Coupling: Data Lines (EFT & Surge), 3PH EUTOutputs: 4 mm banana socketInquire for Availability -
Narda PMM COND-IS/10 RF Conductive Immunity Test System
SKU: 11334
Test Capabilities: RF Conducted ImmunityStandards Met: IEC/EN 61000-4-6Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & ITCDN Test Levels (w/ built-in amplifier): 10VrmsBCI Test Levels (w/ built-in amplifier): 3VFrequency Range (w/ built-in amplifier): 150 kHz - 230 MHzTypically In Stock