Conducted Immunity

(Showing 12 of 53)

Also See - Conducted Immunity Testing - Setup, Systems & More

Rent buy or lease conducted immunity test equipment for pre-compliance and certification. The EMC Shop specializes in RF, electrical transient and other electromagnetic compliance test standards.

Verifying your products vulnerability to unexpected electrical transients was once a tedious task and often overlooked. Manufacturers sending their DUT's to test labs only to be sent back not conforming. With pre-programmed scripts for most commercial and military standards, many firms are bringing the capability in house, allowing engineers to hook up and auto run the test to meet IEC, Mil-Std, ISO, CE marking and more.

OVERVIEW OF CONDUCTED IMMUNITY TESTS

CONDUCTED IMMUNITY TEST EQUIPMENT

Show 12 24 36 48

Conducted Immunity Categories

Conducted Immunity Test Equipment, Systems & Solutions

  • Thermo Keytek E510A 10kV Surge Generator

    SKU: 10799

    Phase synchronization: ±15° with optional coupler/decoupler
    Pulse current (short circuit): 8/20µs, 0-5.05kA with 2 ohm effective source impedance, ±10%
    Pulse repetition: 1 shot/18 seconds
    Pulse voltage (open circuit): 1.2/50µs, 0-10.1kV ±10% in 1 volt steps
    Repetition time: Adjustable from 300ms to 5s; 1ms resolution
    Typically In Stock
  • Thermo Keytek ECAT Transient Generator System

    SKU: 11321

    Pulse current (short circuit): Selectable at 200A max. or 500A max., when the open-circuit voltage is set to 6.0kV.
    Pulse repetition: 1 shot/9 seconds
    Pulse voltage (open circuit): 200V - 6.6kV ± 10%
    Ringwave 0.5 μs/100 kHz: Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41
    Standards Met: ANSI/IEEE C62.41 Cat. A and B, and various UL standards, including UL 864
    In Stock
  • Schloder CWG 1500 Surge Generator, 4.4 kV, 2.2 kA, EN/IEC 61000-4-5

    SKU: sku-783

    Condition (5-10 Scale): 9
    Warranty: 6 Months
    Calibration: Fresh w/ Data at Time of Order
    Test standard: IEC 61000-4-5
    Accessorries: Complete
    Input: 120VAC/1PH
    Phase synchronization: 0 - 359°, step 1° net sync. triggering
    Polarity: pos / neg / alternate
    Pulse current (short circuit): 0.1 - 2.2 kA
    Pulse voltage (open circuit): 0.2 - 4.4 kV
    Test duration: 10 - 990 sec
    $7,950.00
    1 LEFT
  • EMC Partner CDN-KIT1000 ED3

    SKU: 35425

    Standard: IEC 61000-4-5
    Application: surge on 2 unsymmetrical lines
    Test level surge: max. 6 kV
    EUT voltage per line: max. 200 V DC or 240 V peak
    EUT current per line: max. 4 A cont. or 5 A for 5 min.
    Typically In Stock
  • EM Test OCS 500N6F Simulator for Fast/Slow Damped Oscillatory Waves and Ringwave

    SKU: 10413

    Burst duration: 50 ms ±20%, at 3 MHz 15 ms ±20%, at 10 MHz 5 ms ±20%, at 30 MHz
    Damping Rate: Peak 5 to be more than 50% of peak 1 value Peak 10 to be less than 50% of peak 1 value
    Oscillation Frequency: 3 MHz, 10 MHz and 30 MHz, ±10%
    Source Impedance: 50 ohm ±20%
    Voltage: Voltage (o.c.) at HV output 450 V - 4,400 V ±10%
    Burst Duration: At least 2s
    Damping Rate-2: Peak 5 to be more than 50% of peak 1 value Peak 10 to be less than 50% of peak 1 value
    Fast Damped Oscillatory Waves: As Per EN/IEC 61000-4-18
    Frequency: 100 kHz ± 10%
    General Data: Technical Details
    Impedance: 12ohm and 30ohm ± 20%
    Oscillation Frequency-2: 100kHz and 1MHz ± 10%
    Peak current: Max. 500A @ 12ohm or Max. 200A @ 30ohm internally;
    Polarity-2: Positive, negative
    Pulse repetition: 1 to 60 transients per minute
    Repetition Rate: Max. 5,000 /s ±10%
    Ringwave 0.5 μs/100 kHz: Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41
    Source impedance: 200ohm ± 20%
    Spike frequency: 100kHz ± 10%
    Test Voltage: 250 V - 6,000 V ± 10%
    Inquire
  • 3ctest SG 5010H 10kV Surge Simulator for IEC 61000-4-5, GB/T, ITU-T K21/K44

    SKU: sku-326

    Polarity: +/-, positive first or negative first
    Weight: Approximately 300 kg
    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Coupling: 1 or 3 Phase 16 Amps 250V/450V
    Impedance: 500Ω±10%
    Input voltage UIN: AC220V±10%,50/60H
    Output Current: 10/700 and 5/320±20%μs
    Polarity-2: +/-, positive first or alternate
    Pulse current (short circuit): 150A - 3kA/5kA (±10%)
    Pulse voltage (open circuit): 300V - 6kV/10kV (±10%)
    Standards Met: EN/IEC 61000-4-5, IEC 61643-1, GB/T 17626.5m GB/T 16927.1, ITU-T K21 and ITU-T K44
    Telecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendations
    Test duration: Voltage - 50μs(±20%); Current - 20μs(±20%)
    Test Voltage: 300V~6Kv/10kV (±10%)
    Transfer Impedance: 15Ω、40Ω(25+15Ω
  • Teseq NSG 3060-ITU Transient Generator for Surge, Telecom, EFT/Burst, IEC and ITU-T.K

    SKU: 10406

    Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & Variations
    Standards Met: IEC/EN 61000-4-4, IEC/EN 61000-4-5, IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & IT
    Max EUT AC Voltage (w/ Built in CDN): 264 Volts
    Max EUT AC Current (w/ Built in CDN): 16 Amps
    Max EUT DC Voltage (w/ Built in CDN): 220 Volts
    Max EUT DC Current (w/ Built in CDN): 10 Amps
    Peak inrush current capability: 500 A (at 230 V)
    EFT/Burst Pulse Output Capability: ±200 V to 4.8 kV (in 1 V steps) - open circuit±100 V to 2.4 kV ±100 A to 2.2 kA
    Combination/Wave Surge Output Capability: ±200 V to 4.4 kV (in 1 V steps)
    External Coupling: Data Lines (EFT & Surge), 3PH EUT
    Coupling: ANSI / IEC / external
    Phase synchronization: asynchronous, synchronous 0 to 359º (in 1º steps)
    Polarity: positive / negative / alternate
    Test duration: 1 s to 1000 h
    Burst (EFT) 5/50 ns: Pulse conforms to IEC/EN 61000-4-4
    Burst frequency: 100 Hz to 1000 kHz
    Burst time: 1 μs to 1999 s, single pulse, continuous
    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Coupling-2: ANSI / IEC / external
    Impedance: 2/12 Ω
    Output Current: 5 to 500 A
    Phase synchronization-2: asynchronous, synchronous 0 to 359º (in 1º steps)
    Polarity-2: positive / negative / alternate
    Pulse amplitude: ±200 V to 4.8 kV (in 1 V steps) - open circuit; ±100 V to 2.4 kV (50 Ω matching system)
    Pulse current (short circuit): ±100 A to 3.3 kA
    Pulse repetition: 5* to 20 s, up to 600 s (in 1 s steps) * derated depending on selected pulse voltage and EUT supply voltage
    Pulse voltage (open circuit): ±200 V to 6.6 kV (in 1 V steps)
    Repetition Rate: 10 to 600 s
    Repetition time: 1 ms to 4200 s (70 min)
    Telecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendations
    Test duration-2: 1 to 9999 pulses, continuous
    Test Voltage: 200 to 7.7 kV
    Transfer Impedance: 15 and 40 Ω
    Inquire for Availability

Connect with The EMC Shop