Categories
Test Equipment, Systems & Solutions
-
Teseq CDN M016 Switchable 16 Amp Coupling/Decoupling Network
SKU: 10827
Associated Equipment: RF Conducted Immunity Test SystemsApplication/Test Type: switchable 2 or 3 power lines, (L+N or L+N+PE)Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 16 AmpsDecoupling of Common Mode Disturbance: 150 kHz: Greater than 30 dB 1.5 MHz: Greater than 60 dB 30 MHz: Greater than 40 dB 230 MHz: Greater than 20 dBDimensions: 3.9" x 3.9" x 9.5" (100 mm x 100 mm x 240 mm)Frequency Range: 150 kHz to 230 MHzInsertion Loss: Less than 0.1 dBMains & EUT Connections: 4 mm bananaRF Connector: BNC 50 ΩRF Input Voltage: 30 Volts (Max)Standards Met: IEC/EN 61000-4-6Voltage Division Factor: 150 kHz to 80 MHz: 9.5 dB ±1 dB 80 MHz to 230 MHz: 9.5 dB +3 dB / -2 dBVoltage Rating: AC max. voltage (line to ground): 250 V DC max. voltage (line to ground): 400 V; 3 kV DC, 2 sec$195.00Typically In Stock -
Ophir Model 5022 RF Broadband Amplifier, Class A/AB, 1.0-2.0 GHz, 40 Watt, 48 dB Gain
SKU: sku-816
Weight: 37 LBsDimensions: 19” x 5.25” x 20”Frequency Range: 1.0 - 2.0 GHzGain: 48 dBImpedance: 50 ohmsInput: 100 – 240 VAC, single phaseOutput: 40 WattsRF Connector: Type N female$8,100.00 -
Fischer F-35A 100 Hz – 108 MHz Current Monitor Probe
SKU: 1819
Aperture: 32 mmConnector type: Type-NDimensions: Internal diameter: 32 mm External diameter: 98 mm Height: 38 mmFrequency range: 100 Hz – 100 MHzGeneral Data: Technical DetailsHigh frequency 3dB cut-off: 108 MHzLow frequency 3dB cut-off: 100 HzMaximum peak current: 100 AmpsOutput resistance: 50 OhmsProbes: Current monitoring$195.00In Stock -
Teseq NSG 4070C-80 Integrated Signal Generator, 4 kHz to 1 GHz, 80 W Integrated Class A Power Amplifier
SKU: sku-809
Test Capabilities: RF Conducted ImmunityStandards Met: IEC/EN 61000-4-6Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & ITCDN Test Levels (w/ built-in amplifier): 40VrmsBCI Test Levels (w/ built-in amplifier): 8VrmsFrequency Range (w/ built-in amplifier): 150 kHz - 230 MHzTypically In Stock -
Keysight E4419B EPM Series Dual-Channel Power Meter, Battery Operated, 9 kHz to 110 GHz, –70 dBm to +44 dBm
SKU: sku-807
Weight: 4.1 kg (9.0 lb) netDimensions: 212.6 mm W x 88.5 mm H x 348.3 mm D (8.5 in x 3.5 in x 13.7 in)General Data: Technical DetailsRF Field Probe Frequency Range: 9 kHz to 110 GHzRF Field Probe Power Measurement Range: –70 dBm to +44 dBm (100 pW to 25 W), sensor dependentSupply Voltage: Battery$350.00 -
Amplifier Research PM2003 Power Meter, 3 Channel, 10 kHz - 40 GHz, -70dBm to +44dBm
SKU: sku-805
Weight: 7 lbs (3.2 kg)Dimensions: 8.25 in (21.0 cm) wide, 3.5 in (8.9 cm) high, 13.25 in (33.7 cm) deepRF Field Probe Connector: Inputs: Rear panel HEAD connectors and rear panel IEEE-488 connector standard. Outputs: Rear panel PWR/REF connector, 0dBm, 50 MHz. Rear panel RECORDER BNC connector, 0 to 10V into 1mW.RF Field Probe Frequency Range: 10 kHz-40 GHz, power head dependentRF Field Probe Maximum Input Power: May be operated into 1kW or 1V fsRF Field Probe Power Measurement Range: -70dBm to +44dBm, power head dependent -
Noiseken LSS-15AX Series Lightning Surge Simulator up to 15kV
SKU: sku-800
Weight: 200 kg.Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5Coupling: AC/DC lines CDN, and Telecom lines CDNDimensions: 555 X 1250 X 790 mmImpedance: 2 OhmMains & EUT Connections: 4mm banana plugPhase synchronization: 0°-360°, 1°step or randomPolarity: Positive, Negative, AlternatePulse current (short circuit): 15kV/7500APulse repetition: 20 secPulse voltage (open circuit): 15kV/7500AStandards Met: IEC 61000-4-5Inquire for Availability -
Schloder M Type CDN's for Disturbance Signals to Unscreened Supply Lines (mains) AC + DC up to 1000V, 100A
SKU: sku-791
Application/Test Type: unscreened supply lines (mains) AC + DCCurrent Rating: 16A / 32A / 63 A / 100 ADimensions: 160 x 84,5 x 240mm or 200 x 122,5 x 400mm depending on modelFrequency Range: 150 kHz to 230 MHzMains & EUT Connections: banana socketsRF Connector: 50 Ω BNC (Female)Standards Met: IEC / EN 61000-4-6Voltage Rating: up to 250 VAC / 400 VDC -
3 Phase EFT/Burst, Surge Combination Wave Test System
SKU: 1785
Application/Test Type: CE Marking, EMC Precompliance TestingBurst (EFT) 5/50 ns: Pulse conforms to IEC/EN 61000-4-4Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5Pulse amplitude: 0.2 – 5.0 kVPulse current (short circuit): 0.1 – 2.5 kA ±10% (8 us ±20% risetime)Rentals Ship Today -
Schloder VIS 1700 Voltage Interruption Simulator
SKU: sku-784
Communication: BNC outputs (on rear) for voltage, current and scope triggeringCoupling: BNCDips, Interrupts & Variations: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29General Data: Technical DetailsMains & EUT Connections: 4mm banana lineOutput Current: AC max. 280 V, DC max. 3 6 0 VPeak inrush current capability: 16 AmpsPhase synchronization: at any phase position 0° - 360 °Test duration: 0.1sec - 9990sec, furthermore single event and continuous operationTest Voltage: AC max. 280 V ,DC max. 3 6 0 VApplications: EMC Precompliance Testing, Conducted ImmunityTypically In Stock -
EFT-DLC EFT/Burst Capacitive Coupling Clamp for Data Lines
SKU: 1780
Application/Test Type: Electrical Fast Transients on Data Lines (EFT Burst)Built in Accordance to: IEC 61000-4-4Coupling Length: 1 m (39.4 in)Compatible Impulse Generators: Any EFT/Burst Generators (custom HV cable may be required)RF Connector: Fischer HV ConnectorVoltage Rating: up to 5.0 kV$195.00In Stock -
Rent EM Test TSS 500M2F Telecom Surge Simulator for FCC Part 68
SKU: sku-776
Weight: approx. 35kgApplication/Test Type: Test levels as per FCC part 68Coupling: Telecom ports: Tip to Ground, Ring to Ground, Tip and Ring to Ground Power ports 250V/16A: L toN, L to PE, N to PE , L+N to PEDimensions: 19“ / 6HU,Output Current: 64A – 1,000A (power line) 20 – 200A per wire (surge A)Outputs: 4 mm banana socketPolarity: pos / neg / alternateRise time: Less than 2 usTelecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendationsTest Voltage: 160V – 2,500V ± 10% (power line) 160V – 1,500V ± 10% (surge A)Trigger of bursts: Automatic pulse release