Application Categories
Application
-
MIL-STD-461 RS103 Radiated Susceptibility Test System
SKU: 12852
- Configurable radiated susceptibility test system based on needs, available equipment and any other unique consideration.
- 80 MHz - 18 GHz are commonly configured systems with options to to go up to 26.5 or 40 GHz and down to 2 MHz or 10 kHz. ranges configured
- Achieve field strengths to 200 V/m per MIL-STD-461 RS103 or variations with higher field or pulse levels.
- Rental test equipment and systems typically in stock.
Typically In Stock -
dbSAFE MAX Modular RF Shield Room
SKU: 498001
- Isolation Performance better than 90 dB to 3 GHz, 85 dB to 6 GHz, 80 dB to 18 GHz
- Suitable for testing between 300 MHz and 18 GHz with P50 absorber
- Better isolation and performance from 20 MHz to 1 GHz with ferrite (optional)
- ≥ 90 dB Isolation to 3 GHz, ≥ 85 dB to 6 GHz, ≥ 85 dB to 18 GHz
- External fold out workbench for system equipment and technician
Inquire for Availability -
Teseq/Ametek CTS NSG 4070D RF Test Generator
SKU: 10549
Standards Met: IEC 61000-4-6, MIL-461 CS114, ISO 11452-4, DO-160 Section 20 Conducted SusceptibilityApplications: Bulk Current Injection Testing, RF Conducted ImmunityInternal Amplifiers: 50 or 100 Watts (or none)System Frequency Range: 4 kHz - 1 GHzInternal Amp Frequencies: 150 kHz to 230 MHz or 4 kHz to 400 MHzTypically In Stock -
3ctest GN MT6 Compact EMC Test System
SKU: 10541
Standards Met: IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-11Applications: Conducted Immunity Testing, CE Marking, Medical DevicesMax EUT Voltage (w/ Built in CDN): 400 VoltsMax EUT Current (w/ Built in CDN): 20 AmpsPeak inrush current capability: 500 Amps (up to 2.5 kA)Typically In Stock -
R&S RF Power Meter & Sensor Rental Package
SKU: 45448
Frequency Range: DC - 60 GHzTest Standards: IEC/EN 61000-4-3, DO-160 Section 20RF Meter Channels: 1 to 4Interface: GPIB, USB, LANTypically In Stock -
RFCI-75 RF Conducted Immunity Generator, 100 kHz - 400 MHz
SKU: 8467
Test Capabilities: RF Conducted ImmunityStandards Met: IEC/EN 61000-4-6, ISO 11452-4Applications: Vehicle Component Disturbance Testing, CE Marking, Medical Devices, Industrial Machinery, Electronics & ITCDN Test Levels (w/ built-in amplifier): 50VrmsBCI Test Levels (w/ built-in amplifier): 10V/400mA/114 dBµATypically In Stock -
Schwarzbeck VHBD 9134-4 + BBAE 9179 Radiating Elements
SKU: 11816
Applications: Radiated susceptibility, Automotive Immunity testing, aerospace and defenseFrequency Range: 20 - 200 MHzMax RF Input Power: up to 4kW (VHBD 9134-4 Balun)Input Connector: 7/16 DIN (N-type optional for reduced input power)- Tailored to requirements for automotive emc immunity testing
Typically In Stock -
EN/IEC 61000-4-6 30 V/m Level 4 BCI Test Package
SKU: 53194
Standards Met: IEC/EN 61000-4-6BCI Test Levels (w/ built-in amplifier): 30 V/mFrequency Range (w/ built-in amplifier): 150 kHz - 230 MHzApplication: BCI Test Setup$1,975.00 - $3,250.00In Stock -
3ctest EDS MAX30 ESD Simulator Gun
SKU: 141242
Output Voltage Range: 200 Volts to 30,000 VoltsVoltaage Resolution: 100VHolding Time: 5 - 10 sTest Standards: ISO 10605, IEC/EN 61000-4-2:2025Remote & Automation Control: Via fiber optic interfaceTypically In Stock -
3ctest EDS MAX20 ESD Generator
SKU: 832111
- Lightweight and easy to setup custom test sequences, discharge tips and R/C requirements
- Built in temperature and humidity meter with real time monitoring
- High definition touch screen interface
- All 3ctest ESD guns output current waveform that complies with the latest edition of EN/IEC 61000-4-2
- Automation software for robotic arm configuration available
$850.00 - $11,250.00Typically In Stock -
Narda FieldMan 0 Hz to 90 GHz All-in-One Electromagnetic Field Meter
SKU: 12955
Frequency Range: 0 Hz/1 Hz/100 kHz to 90 GHzLogging Info: Temperature, Humidity, Air Preassure, Geolocation, Distance to GroundElectric Field Units: V/m, mW/cm2 , W/m2 , % of standard (depending on the connected probe)Magnetic Field Units: A/m, Tesla, Gauss, mW/cm2 , W/m2 , % of standard (depending on the connected probe)Compliance Standards: 2013/35/EU, IEC/EN 62311, ICNIRP 1998, ICNIRP 2010, IEC/EN 62233, GB-8702-2014, EMFV 2016$495.00 - $1,850.00Typically In Stock -
Langer HR-E 40-1 - 40 GHz Near Field Probe
SKU: 8897
Frequency Range: up to 40 GHzlower cut-off frequency: depending on measuring deviceInner distance of the measuring electrode to the measuring tip: 0.5 mmResolution: 0.2 mmConnector: 2.92 mm (K), female$345.00 - $3,750.00In Stock