Elgar SW1850A SmartWave High Performance Power Source

Condition:
Used
  • Compliance testing for Airbus, DO-160 and Boeing standards
  • 1850 VA Output Power
  • 2Hz to 6kHz standard output frequencies
  • Parallel up to 22.2KVA
Output Power Rating:
1850 VA
AC / DC Output Voltage:
0 - 156 VRMS L-N range 0 , 0 - 312 VRMS L-N range 1
Output Frequency:
DC, or 40 Hz to 5 kHz
Crest Factor:
3.25
Power Factor:
0 to Unity
External Gain Control:
0 to ±7.07 VDC provides zero to full output (±2% of full scale output)
HOG:
Y

 

No reviews yet Write a Review
$1,250.00
Availability:

In Stock

SKU:
11162-MO

 

Due to tariff increases, some items in our catalog are subject to additional costs when purchased.

 

 


Getting Started...

Overview

The Elgar SW1850A SmartWave High Performance AC/DC Power Source offers powerful waveform creation for ATE and power line disturbance simulation testing. Separate arbitrary waveform generators enable to SmartWave to create independent, complex waveforms on phases simultaneously. The SmartWave is designed to meet waveform requirements including DC content (up to 312V), low distortion (THD 0.25% to 100Hz), low noise and ripple, plus full compliance testing to many EMC and avionics standards. The SW1850A can easily create fractional or multicycle dropouts, spikes, surges, sags, and distorted waveforms via an extensive library of 50 built-in waveshapes. 

Applications

  • Testing for real world power conditions (3 phases including DC)
  • Load susceptibility testing with sequence or event programming and multiple voltage harmonics
  • Power line disturbance simulation testing
  • MIL-STD-704 , DO-160 , and ABD100 avionics testing
  • Power supply testing for AC-DC , DC-DC converters and UPS's
  • Fluorescent lighting characteristics testing (IES LM-41-1985)
  • Transients on 12 & 24 VDC for automotive applications

The Elgar SW1850A SmartWave High Performance AC/DC Power Source is in stock and available for same-day shipping on rentals. The EMC Shop is an ISO 17025 accredited calibration lab. Calibrations are available upon request (allow 1-2 additional days).

Videos

Key Considerations

Output Power Rating:
1850 VA
AC / DC Output Voltage:
0 - 156 VRMS L-N range 0 , 0 - 312 VRMS L-N range 1
Output Frequency:
DC, or 40 Hz to 5 kHz
Crest Factor:
3.25
Power Factor:
0 to Unity
External Gain Control:
0 to ±7.07 VDC provides zero to full output (±2% of full scale output)
HOG:
Y

Downloads