  • Programmable output & test limit
  • Standard USB, RS232, & HANDLER interfaces
  • Ground Fault Interrupt (GFI) for human protection circuit
  • Discharge Level Analysis (DLA) mode provides detection of Flashover and Breakdown (high limit)
  • Flashover (ARC) detection allowing discharge analysis through full voltage range.
Output Voltage:
DC: 0.1 - 12 kV
Load Regulation:
± (1% of output + 10V), Rated load
Voltage Accuracy:
± (1% of setting + 0.1% of full scale)
Cutoff Current:
0.0001 - 10mA
Insulation Resistance Test:
0.1 MΩ - 50 GΩ
HOG:
Y

 

No reviews yet Write a Review
$375.00
Availability:

In Stock

SKU:
9612-RE

 

Due to tariff increases, some items in our catalog are subject to additional costs when purchased.

 

 


Getting Started...

Overview

Includes

  • Associated Research European Adapter Box
  • Associated Research American Adapter Box
  • Return Cable

The Chroma 19057 Hipot Analyzer is specifically designed for testing and analyzing ultra-high withstand voltage. This model includes 10 kVac / 12 kVdc / 20 kVdc with maximum AC 20 mA/DC 10 mA output capable of performing AC/DC withstand voltage and insulation resistance tests as well as contact check for production line testing. In addition to the Open Short Check (OSC), High Voltage Contact Check is added to test the components with high insulation capability for high voltage output to improve the testing reliability and efficiency. 

 

Applications

The 19057 Hipot Analyzer mainly provides high withstand voltage test and analysis for optical couplers, HV relays, HV switches, and PV modules components, which have greater insulation capability. 

This unit features a Flashover (ARC) detection function enabling discharge level analysis through the start voltage, end voltage, and number of steps and time. Discharge Level Analysis (DLA) mode provides detection of Flashover and Breakdown (high limit). 

External Oscilloscopes can be used with the unit to check the waveform at the same time during analysis. Analysis of the test results allows R&D engineers to understand how to increase quality and performance of insulation components.

The Chroma 19057 Hipot Analyzer is in stock and available for same-day shipping on rentals. The EMC Shop is an ISO 17025 accredited calibration lab. Calibrations are available upon request (allow 1-2 additional days).

Videos

Key Considerations

Manufacturer:
Chroma
Output Voltage:
DC: 0.1 - 12 kV
Load Regulation:
± (1% of output + 10V), Rated load
Voltage Accuracy:
± (1% of setting + 0.1% of full scale)
Cutoff Current:
0.0001 - 10mA
Insulation Resistance Test:
0.1 MΩ - 50 GΩ
HOG:
Y