3-Phase Surge CDN's Test Equipment, Systems & Solutions
-
Teseq CDN 3083-Surge 620 Volt, 100-200 Amp Manual Coupler
SKU: sku-220
Weight: 80 kg (176 LB's)Application/Test Type: Manual Surge Testing for EUT up to 100Amps, 620 VAC; Three phase (5 wire); Two phase (4 wire); Single phase (3 wire)Current Rating: 100 Amp or 200 Amp continous depending on modelDimensions: 850 x 520 x 345 mmMains & EUT Connections: Fischer 105 series; Screw terminals, rated for 230 ARF Input Voltage: Max. 8 kV / 4 kAStandards Met: IEC / EN 61000-4-5:2005, ANSI C62.45 standard, in IEC / EN 61000-4-12:2006 and ANSI C62.41Voltage Rating: 620 VAC RMS L-to-L (max. 440 V for NSG 3040 and Modula); 620 VAC RMS L-to-PE (max. 440 V for NSG 3040 and Modula); 620 VDC -
Haefely FP-SURGE 100M 100 Amp Surge Immunity System
SKU: sku-2170
Test Capabilities: Combination Wave Surge ImmunityStandards Met: IEC/EN 61000-4-5 ANSI standards C62.41 and C62.45Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & ITMax EUT AC Voltage: 690 VoltsMax EUT Current: 100 AmpsImpulse Voltage: 8 kVImpulse Current: 4 kARENTAL ONLY -
In Stock
-
Inquire for Availability
-
Haefely FP-COMB 32 Automatic 3-Phase Coupler for AXOS System
SKU: sku-786
Burst (EFT) 5/50 ns: Pulse conforms to IEC/EN 61000-4-4Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5Pulse amplitude: 5 kVVoltage: 7 kVCompatible Impulse Generators: Haefely AXOS5, Haefely AXOS8Typically in Stock -
Teseq CDN 3083-Burst 1000 Volt, 100-200 Amp Coupler for EFT/Burst
SKU: sku-221
Weight: 11 kg (24 lbs)Application/Test Type: EFT/Burst immunity testing of equipment requiring large currents, specially designed for heavy industry, smart grid and electro vehicle applications.Current Rating: 100 Amp or 200 Amp continous depending on modelCompatible Impulse Generators: Any EFT/Burst Generators (custom HV cable may be required)Mains & EUT Connections: SHV; Screw terminals, rated for 200 AStandards Met: IEC / EN 61000-4-4 up to 8.8 kVVoltage Rating: 690 V AC RMS; 1000 VDC$395.00In Stock -
3ctest EFTN CDN for Burst, Three Phase 5-wire, AC 380V, 32A, Max 440V
SKU: sku-564
Weight: approx. 50KgBurst (EFT) 5/50 ns: Pulse conforms to IEC/EN 61000-4-4Burst frequency: 0.1kHz–1000kHzDimensions: 19 inch/6UExternal: External control: 25Pin D-BusPhase synchronization: 0° - 360°, 1° step or randomPolarity: +/-Pulse amplitude: 0.25 kV -4.8kV, ± 10%Inquire for Availability -
Haefely PCD 130 3 Phase Coupling/Decoupling Network for PSURGE 8000
SKU: sku-444
Weight: 69 kg (net weight)Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5Coupling: 3 Phase - 32 Amps, 690 VACDimensions: 45 x 50 x 57 cm (W x H x D)General Data: Technical DetailsPhase synchronization: 1° stepsPolarity: pos / negPulse current (short circuit): 32A RMSPulse voltage (open circuit): 690V RMS (Phase-Phase) 110V DCStandards Met: IEC 61000-4-5 Ed. 1 & 2 and ANSI C62.41 and C62.45In Stock -
3ctest SPN Series CDN's for Lightning Surge, Single Phase 3-wire, Three Phase 5-wire
SKU: sku-563
Weight: approx. 50KgDimensions: 19 inch/6UImpedance: 2 ohm (output)Polarity: +/-/alternativeVoltage: 0.2kV–6kV,±10%Inquire for Availability -
3ctest SEPN Series CDN's for Surge & Burst, Single Phase 3-wire, Three Phase 5-wire
SKU: sku-561
Polarity: +/-Weight: approx. 50KgBurst (EFT) 5/50 ns: Pulse conforms to IEC/EN 61000-4-4Burst frequency: 0.1kHz–1000kHzCombination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5Dimensions: 19 inch/6UImpedance: 2 ohm (output)Oscillation Frequency: Current waveform: Front time: 8us±20%, time to half value: 20us±20%Polarity-2: +/-/alternativePulse amplitude: 0.25 kV -4.8kV, ± 10%Pulse current (short circuit): 0.1kA–3kA,±10%Voltage: 0.2kV–6kV,±10% -
Teseq CDN 3063-S63 3 Phase, 63 Amp Automated Surge CDN Coupler for NSG 3040/3060
SKU: sku-218
Weight: 100 kg (220.5 lb)Application/Test Type: Automated Surge Testing for EUT up to 63 Amps, 480 VAC; Three phase (5 wire); Two phase (4 wire); Single phase (3 wire)Current Rating: 3 x 63 Amp continuous (peak 3 x 100 Amp for 30 min.)Dimensions: 570 x 840 x 630mm (22.4 x 33 x 24.8")Frequency Range: DC – 65 Hz with no loss, 400 Hz max. with power lossMains & EUT Connections: HV-surge pulse input from generator (Fischer connector); Connector for EUT supply input (Screw terminals Phoenix); Connector for EUT supply output (Screw terminals)Standards Met: IEC / EN 61000-4-5:2005, ANSI C62.45 standard, in IEC / EN 61000-4-12:2006 and ANSI C62.41Voltage Rating: EUT VAC line to line: 30 to 480 VAC rms; EUT VAC line to ground: EUT VAC 30 to 280 VAC rms, (below 30 V synchronisation not guaranteed, asynchronous mode only); EUT VDC: up to 125 VDC – full current range, up to 225 VDC – up to 7 AInquire for Availability -
Teseq CDN 3063-S100 Automated Surge CDN Coupler - 3 Phase, 100 Amp, 480 Volts
SKU: sku-219
Application/Test Type: Automated Surge Immunity TestingCurrent Rating: 3 x 100 Amp continuous (peak 3 x 150 Amp for 30 min.)Mains & EUT Connections: HV-surge pulse input from generator (Fischer connector); Connector for EUT supply input (Screw terminals Phoenix); Connector for EUT supply output (Screw terminals)Standards Met: IEC / EN 61000-4-5:2005, ANSI C62.45, IEC / EN 61000-4-12:2006 and ANSI C62.41Voltage Rating: 480 VAC rms Line to LineInquire for Availability