Power Fail Simulators

(Showing 12 of 19)

The EMC Shop stocks a wide selection of Power Fail Simulation (micro-interruptions) for Automotive and Commercial EMC testing. Rent or buy power fail simulators for individual tests or multifunction generators to complete an assortment of tests in a compact solution. Most systems can be easily upgraded to include additional tests as required.

Get Application Support, Pricing, Lead Time and More: CONTACT FORM

Power Fail Simulation EMC test generators are typically benchtop, but heavy equipment. When doing testing on three phase power lines systems usually require much larger coupling/decoupling networks which substantially increase system size. EM test environments with ground planes with connections to earth are required to safely use transient generators.

Common Power Fail Simulators EMC Compliance Tests

  • BMW GS 95003-2
  • BMW GS 95024-2-1
  • Chrysler CS-11809 (2009)
  • Chrysler CS-11979
  • Chrysler PF-9326
  • Cummins 14269 (982022-026)
  • DaimlerChrysler DC-10615
  • DaimlerChrysler DC-10842
  • DaimlerChrysler PF-10541
Show 12

Power Fail Simulators Test Equipment, Systems & Solutions

  • York EMC HFG01 Harmonic and Flicker Generator

    SKU: 6822

    Test supply connector: 1.3 m captive lead with CEE 7/7 mains plug for connection to test equipment
    Power Supply: External power supply, 24 V DC, 1A maximum
    Indicators: Thermal shutdown
    Harmonic current: Up to 40th harmonic: 50 Hz to 2 kHz
    Flicker disturbance: 1 Hz and 8.33 Hz
    Dimensions: 330 mm × 320 mm × 170 mm
    Weight: 6.5 kg
    IN STOCK
  • Noiseken VDS-2002 Voltage Dip and Swell Simulator

    SKU: NO-VDS-2002

    Compliant Standard: IEC 61000-4-11 (1994) 、IEC 61000-4-11 (2004) at Output voltage 0 to 100%
    Input voltage from EUT: AC100〜240V±10% 50/60Hz
    Interface: Optical interface Optional optical converter RS-232 or USB selection
    Operating temperature: 15〜35℃
    Operating humidity: 25〜75%R.H.
    External dimensions / Weight: (W)430 x (H)745 x (D)600mm(excluding protrusions) / approx.150kg
    Power consumption: 120VA (AC100〜240V 50/60Hz)
  • Rent Chroma 61605 Single Phase AC Power Source

    SKU: sku-2125

    Weight: 71 kg/165.2 lbs
    Current rating: 120 amps
    Dimensions: 400 x 482 x 600 mm (15.75 x 19 x 24 in)
    Frequency Range: DC, 15 Hz - 1.2 kHz (.15% accuracy)
    Output current: 16 Amps RMS (96 Amps Peak)
    Output voltage: 6000 VA max, 2000 VA per phase
    Voltage ranges: 150-300 Volts
    $1,295.00
  • California Instruments 1501iX Programmable AC Power Source

    SKU: sku-2100

    Weight: per Chassis: Net: 61 lbs / 28 Kg, Shipping: 115 lbs / 52 Kg
    Current rating: 120 amps
    Dimensions: Height: 7” (178 mm), Width: 19” (483 mm), Depth: 24” (610 mm) (depth includes rear panel connectors)
    Frequency Range: 16.00 - 81.91 Hz (0.01 Hz resolution) 81.0 – 819.1 Hz (0.1 Hz resolution) 820 – 1000 Hz (1 Hz resolution)¹
    Voltage ranges: 150-300 Volts
  • Schloder VIS 1700 Voltage Interruption Simulator

    SKU: sku-784

    Communication: BNC outputs (on rear) for voltage, current and scope triggering
    Coupling: BNC
    Dips, Interrupts & Variations: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
    General Data: Technical Details
    Mains & EUT Connections: 4mm banana line
    Output Current: AC max. 280 V, DC max. 3 6 0 V
    Peak inrush current capability: 16 Amps
    Phase synchronization: at any phase position 0° - 360 °
    Test duration: 0.1sec - 9990sec, furthermore single event and continuous operation
    Test Voltage: AC max. 280 V ,DC max. 3 6 0 V
    Typically In Stock
  • 3ctest PFS 2216SVD Single Phase Power Fail Simulator w/ Two Semiconductor Switches for High Current Protection

    SKU: sku-591

    Weight: 40Kg
    Communication: Ethernet LAN、RJ45
    Coupling: BNC
    Dimensions: 19 inch/6U
    Dips, Interrupts & Variations: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Frequency: 45-65Hz
    General Data: Technical Details
    Input: BNC,5V TTL
    Mains & EUT Connections: 4mm banana line
    Maximum Continuous Power: 100W
    Output Current: 16A AC/DC continuous current; 20A continuous 5s 40Acontinuous 3s
    Peak inrush current capability: 500 Amps
    Phase synchronization: 0°- 360°,1° step or random
    Repetition time: 0.3-9999 cycle or 5ms-9999ms
    Rise time: 1-5us(100Ω load)
    Supply Voltage: 110V/220V, ±10%, 50/60Hz
    Test duration: 50ms-50000ms
    Test Voltage: 250V AC,300V DC
    Trigger: BNC,5V TTL
  • 3ctest PFS 2216SD Power Fail Simulator for EN/IEC 61000-4-11

    SKU: sku-590

    Mains & EUT Connections: 4mm banana line
    Output Current: 16A AC/DC continuous current; 20A continuous 5s 40Acontinuous 3s
    Peak inrush current capability: 500 Amps
    Rise time: 1-5us(100Ω load)
    Test duration: 50ms-50000ms
    Test Voltage: 250V AC,300V DC
    Trigger: BNC,5V TTL
    Inquire for Availability
  • 3ctest PFS 6030A Power Failure Simulator for Voltage Dips & Drops,60 V / 30 A

    SKU: sku-588

    Test voltage: Voltage drop: 1V max@30A
    Weight: 20 kg
    Dimensions: 19" / 4 U
    Output: DUT voltage monitoring output: BNC,10:1 coaxial terminal output DUT current monitoring output: BNC,10A:1V coaxial terminal output
    Peak current: 60A duration time 500 ms
    Pulse duration: Drop duration time td 1us - 10 s
    Repetition rate: 100 ms - 999s
    Source Impedance: High resistance or low resistance
    Test Voltage: 0–60 V
    Trigger: External trigger signal by oscilloscope, BNC,5V TTL
    Trigger of bursts: Automatic, manual, external
  • EM Test PFS 503N32 Power Fail Simulator, 3-phase 3x480V AC (p-p) max. 32A

    SKU: sku-549

    Weight: app. 28kg;
    Current Rating: Max. 32A
    Dimensions: 19"/6 HU
    Dips, Interrupts & Variations: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Frequency: 50Hz/60Hz, Single phase application
    Output: 3-phase application L1, L2, L3, N and PE on the rear panel. 1-phase application L, N and PE on the front panel
    Peak current: Better than 500A
    Repetition rate: 0.01s to 9,999s
    Rise time: Between 1us and 5us for abrupt changes, generator loaded with resistive load
    Supply Voltage: 115V/230V; +10/-15%
    Test Voltage: 3x480V AC resp. 3x690V AC (L-L) 277V AC resp. 400V AC 360V DC resp. 600V DC (L-N)
    Trigger of bursts: Automatic

Connect with The EMC Shop