Overview
EM Test CWS 500N4 Description
The EM Test CWS 500N4 is the state-of-the-art solution in a compact single-box design to test for immunity to conducted, common mode disturbances in the frequency range 0Hz (DC) to 165kHz. Such test requirements are specified in IEC 61000-4-16 and cover continuous mode testing as well as short term testing with DC, 16 2/3Hz, 50Hz and 60Hz with 4 test levels each plus a sweep mode from 10Hz to 165kHz. Additionally, the CWS 500N4 can be used for testing electricity metering equipment as per prTR 50579 and Draft standard IEC 61000-4-19, Annex C.
- IEC 61000-4-16
- IEC 60255-22-7
- IEC 60255-26
- IEC 60533
- EN 61000-4-16
- IEC 61000-4-19
- Annex C
- IEC 61326
- IEC 61543
- IEC 61850-3
- prTR 50579
Benefits
The CWS 500N4 is able to generate all continuous mode test levels up to 30V (DC, 16 2/3Hz, 50Hz and 60Hz) and the frequency sweep 15Hz to 150kHz without any additional external voltage source.
In order to perform the short-term mode tests up to 300V (DC, 50Hz or 60Hz, depending on the mains line frequency) the optional MV 2606N2.2 is required.
If tests need to be done with 16 2/3Hz or at frequencies other than the mains line frequency the optional programmable AC voltage source ACS 500N2.2 is needed.
Specifications:
- Test frequencies DC, 16 2/3Hz, 50Hz and 60Hz
- Signal level 0.1 - 35 Vrms or DC
- Test level 1 1V continuous
- Test level 2 3V continuous
- Test level 3 10V continuous
- Test level 4 30V continuous
- Output impedance 50ohm ± 10%
- Total harmonics distortion < 10% (sinusoidal waveform) Ripple on DC < 5%
OUTPUT CHARACTERISTICS SHORT-TERM MODE
- Test frequencies DC, 16 2/3Hz, 50Hz and 60Hz
- Signal level 1 - 330Vrms or DC
- Test level 1 10V for 1s duration
- Test level 2 30V for 1s duration
- Test level 3 100V for 1s duration
- Test level 4 300V for 1s duration
- Output impedance 50ohm ± 10%
- Total harmonics distortion < 10% (sinusoidal waveform)
- Phase synchronisation 0° ± 5%
- Ripple on DC < 5%
- Fall/rise time between 1us and 5us Note: These tests require either the optional MV 2606N2.2 motor variac or the optional programmable AC voltage source ACS 500N2.3.
- Frequency range 10Hz to 165kHz
- Signal level 0.1 to 35Vrms
- Test level 1 1V - 0.1V - 1V
- Test level 2 3V - 0.3V - 3V
- Test level 3 10V - 1V - 10V
- Test level 4 30V - 3V - 30V
- Output impedance 50ohm ± 10%
- Total harmonics distortion < 1% (sinusoidal waveform)
Coupling Network Options
- CN 16-L2/L4
- 2-wire/4-wire coupling network, switchable, EUT Umax. AC: 440V 16.7Hz..80Hz, EUT Umax. DC: 125V, GEN IN Umax.: 330V AC/DC, Power dissipation: max. 40W
- CN 16-L2.1
- 2-wire coupling network, EUT Umax. AC: 300V 16.7Hz..80Hz, EUT Umax. DC: 220V, GEN IN Umax.: 330V AC/DC, Power dissipation: max. 200W, active cooling,overtemperature protection, Mains: 85-265 V 50/60Hz, Fuse 1AT
- CN 16-L3
- 3-wire coupling network, EUT Umax. AC: 440V 16.7Hz..80Hz, EUT Umax. DC: 125V, GEN IN Umax.: 330V AC/DC, Power dissipation: max. 40W
- CN 16-L4/690V
- 4-wire coupling network, EUT Umax. AC: 3x690V 50/60Hz, EUT Umax. DC: 125V, GEN IN Umax.: 330V AC/DC, Power dissipation: max. 40W
- CN 16-L8
- 8-wire coupling network, EUT Umax. AC: 300 V 16.7Hz..80Hz, GEN IN Umax.: 330 V AC/DC, EUT Umax. DC: 160V, Power dissipation: max. 40W
- CDN 16-L2
- 2-wire coupling network, decoupling with isolation transformer, EUT Umax./ Imax.: 300V 16A GEN IN Umax.: 330VAC
- CDN 16-L4/400 V
- 4-wire coupling network, decoupling with isolation transformer EUT Umax./ Imax.: 3x480V 16A, GEN IN Umax.: 330VAC CDN 16-T2 Telecom T-network, 60VDC, 2A, EUT Umax.: 60VDC, EUT Frequency range: Telecom applications, GEN IN Umax.: 330V AC/DC