GTEM 500 Radiated Emission and Immunity Testing for IEC/EN 61000-4-20

Condition:
New
Max EUT Size:
16" by 16" by 12.25"
Standards for Emissions Testing:
CISPR 14-1, IEC 61000-6-3 and IEC 61000-6 -4
Standards Met:
IEC/EN 61000-4-20
Manufacturer:
The EMC Shop
Online Orders Ship Same Day

 

Availability:

Typically In Stock

SKU:
sku-2326

 

This product is available for shipping to North America and Western European countries.


Getting Started...

Check out our Google Reviews

GTEM 500 Overview

The GTEM 500 cell is a GTEM waveguide with the upper frequency limit extended to the GHz range. It is a low-cost alternative measurement facility for both radiated emission and immunity measurements. It is included in the recently published standated IEC/EN 61000-4-20 "Emission and Immunity Testing in Transverse Electromagnetic (TEM) Waveguides”. Compared to other measuring methods like EMC test in anechoic chambers or OATS (Open Area Test Sites), GTEM-cells offer some significant advantages for the testing of small and medium sized EUT's.

(Equipment Under Test) up to a frequency range of 20 GHz. Quick turnarounds of the EUT as well as numerous testing variations are easy and fast to handle. Switching from emission to immunity testing requires only simple adjustments from receiver input to amplifier output. You are irrespective of long waiting times associated with off-site test labs or weather and ambient delays that can occur at OATS facilities. Whether you are at the design qualification, precompliance, compliance, or production sampling stage, the GTEM is the right choice for you!

Theory of operation

GTEM 500 cells (Giga-hertz Transversal Electro-Magnetic cells) are waveguide structures intended for electromagnetic compatibility measurements, as well as biomedical applications. The electromagnetic field distribution inside the cell is in TEM mode. With TEM mode propagation, there is no component of electric and magnetic field in the direction of propagation of electromagnetic wave. Therefore the field components are strictly perpendicular. Assuming the field distribution ideal TEM below the cut-off frequency of the cell (before the introduction of higher order modes), the electromagnetic field distribution can be considered static.

Special Configuration includes:

Additional Channel for fiber optic leads (3 fiber pairs) 
Shielded window in door 
High Voltage N Connector 
Qty 6 RF feed-thru SMA type connector 
Qty 2 Air venting window 80x80 mm  



[split]

GTEM 500 Applications

  • EMI and EMS devices
  • Radiation and susceptibility test
  • Specifically designed for telecom application
  • Biomedical and dosimetrical applications
  • Isotropic sensors calibration
  • Receiver sensitivity test

Specifications

 

Operating range

100 kHz - 20GHz

RF Input

Max continuous. input power: 250 W

RF Input connector type

"N" type female connector

Shielding

Better than 65 to 110dB depending from frequencies

Absorbers

350 mm TDK

Outer cell dimension

300X168X115 (LxWxH)

Door Size

40 x 40 (cm)

Construction

Fully INOX steel rugged military grade construction

 

GTEM 500 Installation Manual and General Safety Instructions

The GTEM GigaHertz Transverse Electromagnetic) cell is a precision electromagnetic compatibility (EMC) test instrument primarily intended for use as radiated immunity and radiated emission test facility without environmental electromagnetic interference. The cell is electrically similar to a coaxial cable with one side open (the apex) and other side closed on the impedance of the generator or receiver connected. In this case with a multimeter appears as 50 Ohm resistance.

Measurement Setup

The setup for emission measurements in a GTEM cell is shown below. The EUT is placed inside the GTEM and its radiation is measured with a receiver. The receiver can be software controlled and some software that includes the GTEM to OATS correlation is commercially available.

 

Additional Options for the GTEM 500:

  • High Voltage N type connector
  • Removable metal shielded window blinder (for highest shielding)
  • Honeycomb 10x10cm air vent intake/outtake
  • Shielded RJ45 fiber optic IP camera system
  • 3-axis DUT positioner 
  • Generic inox steel feedthrough for "other" type cables, 20cm long, 1" diameter
  • 9 poles DB9 filtered pass-thru RS-232
  • USB 2.0 shielded feed-thru
  • USB 3.0 shielded feed-thru
  • Shielded RJ45 / RJ11 feed-thru F-F connector
  • Internal LED lighting

GTEM 500 Key Considerations

Manufacturer:
The EMC Shop
Max EUT Size:
16" by 16" by 12.25"
Standards for Emissions Testing:
CISPR 14-1, IEC 61000-6-3 and IEC 61000-6 -4
Standards Met:
IEC/EN 61000-4-20

Connect with The EMC Shop

Our experienced staff can help you with applications, purchase and rental options.