Combination Wave/Surge Generators

(Showing 4 of 28)

The EMC Shop stocks combination wave surge generators for conducted immunity testing and compliance according to IEC 61000-4-5. UL 1449, ANSI C62.41 and more.

See - Surge Immunity Test, Setup, Equipment

Getting Started with a Combination Wave Generator

Combination wave/surge generators are typically benchtop, but heavy equipment. Testing on data and three phase power lines require additional coupling/decoupling networks. Pre programmed test sequences for surge immunity allows you to begin testing once coupling in your EUT and properly grounding the test setup.

MOST RENTED COMBINATION/WAVE GENERATORS

Sold out

/month

Sold out

/month

Sold out

/month

Sold out

/month

Show 12 24

Combination Wave/Surge Generators Test Equipment, Systems & Solutions

  • 3ctest SG 5010H 10kV Surge Simulator for IEC 61000-4-5, GB/T, ITU-T K21/K44

    SKU: sku-326

    Polarity: +/-, positive first or negative first
    Weight: Approximately 300 kg
    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Coupling: 1 or 3 Phase 16 Amps 250V/450V
    Impedance: 500Ω±10%
    Input voltage UIN: AC220V±10%,50/60H
    Output Current: 10/700 and 5/320±20%μs
    Polarity-2: +/-, positive first or alternate
    Pulse current (short circuit): 150A - 3kA/5kA (±10%)
    Pulse voltage (open circuit): 300V - 6kV/10kV (±10%)
    Standards Met: EN/IEC 61000-4-5, IEC 61643-1, GB/T 17626.5m GB/T 16927.1, ITU-T K21 and ITU-T K44
    Telecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendations
    Test duration: Voltage - 50μs(±20%); Current - 20μs(±20%)
    Test Voltage: 300V~6Kv/10kV (±10%)
    Transfer Impedance: 15Ω、40Ω(25+15Ω
  • 3ctest CWS 600CT Combination Wave & Telecom Surge Simulator, 1.2/50us 8/20us 10/700us 5/320us

    SKU: sku-333

    Polarity: Positive, Negative or Alternate
    Weight: Approx 15 kg (33 lbs)
    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Counter: 1-999
    Coupling: Optional for external SPN series CDN's
    Dimensions: 19 inch/6u
    Frequency Range: 50/60Hz±5%
    Front Time: Voltage: 10us±20%, time to half value: 700us±20%;
    Impedance: 2 phm, Optional 12 ohm and 500 ohm
    Mains & EUT Connections: 4mm banana plug
    Output Current: Front time: 5us±20%, time to half value: 320us±20%
    Polarity-2: Positive, Negative and Alternating
    Pulse current (short circuit): 0.15 kA–3.0kA ±10% (2ohm)
    Pulse Duration: 11s-99s (shortest depends on test voltage)
    Pulse repetition: 1-999
    Pulse voltage (open circuit): 0.3kV–6.0kV ±10%
    RF Connector: BNC, 5VTTL
    Standards Met: UL 1449, ANSI C62.41, IEC 61000-4-5, EN & IEC 60255-5, GB/T 17626.5
    Telecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendations
    Test duration: 6s-99s
    Test Voltage: 0.2kV–6.0kV,±10%
    Transfer Impedance: 15ohm, 40ohm (automatic switch)
    Voltage Rating: AC 110V/220V , ±10%,
  • 3ctest CWS 600T 10/700us Telecom Wave Surge Simulator for IEC 61000-4-5

    SKU: sku-330

    Weight: Approx 15 kg (33 lbs)
    Counter: 1-999
    Dimensions: 19 inch/6u
    Frequency Range: 50/60Hz±5%
    Front Time: Voltage: 10us±20%, time to half value: 700us±20%;
    Mains & EUT Connections: 4mm banana plug
    Output Current: Front time: 5us±20%, time to half value: 320us±20%
    Polarity: Positive, Negative or Alternate
    Pulse Duration: 11s-99s (shortest depends on test voltage)
    RF Connector: BNC, 5VTTL
    Standards Met: IEC 61000-4-5 and ITUETSI
    Telecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendations
    Test Voltage: 0.2kV–6.0kV,±10%
    Transfer Impedance: 15ohm, 40ohm (automatic switch)
    Voltage Rating: AC 110V/220V , ±10%,

Connect with The EMC Shop