RF Power Line CDN's Test Equipment, Systems & Solutions
-
EM Test (Lüthi) CDN M3-32 240 Volt Switching Coupling/Decoupling Network
SKU: sku-143
Application/Test Type: Coupling/decoupling networks for Conducted immunity, mains AC power supply linesCurrent Rating: 32 AmpsFrequency Range: 150 kHz to 230 MHzMains & EUT Connections: AE: IEC 60320/C14 connector EUT: 4mm safety lab connectorsStandards Met: IEC / EN 61000-4-6Voltage Rating: 240 V -
EM Test (Lüthi) M1 CDN for Earth Conductor 250V AC / 1,000V DC
SKU: sku-103
Application/Test Type: Coupling/decoupling networks for Conducted immunity, mains AC power supply linesCurrent Rating: 16 Amps (Max)Frequency Range: 150 kHz to 230 MHzMains & EUT Connections: 4mm safety lab connectorRF Input Voltage: 30 V (Max)Standards Met: IEC / EN 61000-4-6Voltage Rating: 250 V AC / 1,000 V DC -
Teseq CDNE M310 Coupling/Decoupling Network for Emission Measurement, 10 A, 30 to 300 MHz
SKU: sku-87
Weight: 700 grams (1.5 LB.'s)Application/Test Type: Emission measurement (CDNE) to measure disturbance voltages in the 30 to 300 MHz frequency rangeCommon Mode Impedance: Common mode impedance (EUT port): 150 Ω +10/-20 ΩCurrent Rating: 10 AmpsDecoupling of Common Mode Disturbance: Greater than 30 dBDimensions: 4.1 x 3 x 5 inches (10.5 x 7.5 x 12.5 cm)Frequency Range: 30 MHz to 300 MHzInsertion Loss: Greater than 0.1 dBMains & EUT Connections: 4 mm, safetyRF Connector: BNC, 50 ΩRF Input Voltage: Less than 10 VoltsStandards Met: CISPR 16-2-1 edition 3.0, CISPR 16-2-1, CISPR 15 and IEC 61000-4-6Voltage Division Factor: 20 dB ±1.5 dBVoltage Rating: C max. voltage (line to ground): 300 V; AC max. voltage (line to line): 520 V; DC max. voltage: 300 V; Tes Voltage: 2000 V AC, 2 s -
Teseq CDN M216 1kV CDN for CISPR 16-1-2, CISPR 16-2-1 and CISPR 15
SKU: sku-86
Weight: 700 grams (1.5 LB.'s)Application/Test Type: Emission measurement (CDNE) to measure disturbance voltages in the 30 to 300 MHz frequency range.Common Mode Impedance: 150 Ω +10/-20 ΩCurrent Rating: 10 Amps MaximumDecoupling of Common Mode Disturbance: Greater than 30 dBDimensions: 4.1 x 3 x 5 inches (10.5 x 7.5 x 12.5 cm)Frequency Range: 150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)Insertion Loss: Greater than 0.1 dBMains & EUT Connections: 4 mm, safetyRF Connector: BNC, 50 ΩRF Input Voltage: Less than 30 VStandards Met: IEC 61000-4-6, CISPR 16-1-2, CISPR 16-2-1 and CISPR 15Voltage Division Factor: 20 dB ±1.5 dBVoltage Rating: AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec -
Com-Power CDN-M225E Coupling Decoupling Network for Unscreened Power Supply Lines
SKU: sku-54
Weight: 5 lbs. 2.3 kgApplication/Test Type: two conductor power cableCommon Mode Impedance: 150 kHz - 26 MHz: 150Ω ± 20Ω 26 MHz - 80 MHz: 150Ω + 60Ω / – 45Ω 80 MHz - 230 MHz: 150Ω + 60Ω / – 60ΩCurrent Rating: 25 Amps AC / 17 Amps DC (Max)Decoupling of Common Mode Disturbance: ≥ 40dB (EUT/AE)Dimensions: 6 x 6 x 13 inches 15.2 x 15.2 x 33 cmFrequency Range: 150 kHz to 230 MHzMains & EUT Connections: 4 mm shrouded banana socketsRF Connector: 50 Ω BNC (Female)RF Input Voltage: 40 V (Max)Standards Met: IEC / EN 61000-4-6Voltage Division Factor: 9.5 dB +4 / -1Voltage Rating: 250 V AC / 350 V DC (Line to Ground) -
Com-Power CDN-M125E Coupling Decoupling Network
SKU: sku-20
Weight: 5 lbs. 2.3 kgApplication/Test Type: Single conductor power cableCommon Mode Impedance: 150 kHz - 26 MHz: 150Ω ± 20Ω 26 MHz - 80 MHz: 150Ω + 60Ω / – 45Ω 80 MHz - 230 MHz: 150Ω + 60Ω / – 60ΩCurrent Rating: 25 Amps AC / 17 Amps DC (Max)Decoupling of Common Mode Disturbance: ≥ 40dB (EUT/AE)Dimensions: 6 x 6 x 13 inches 15.2 x 15.2 x 33 cmFrequency Range: 150 kHz to 230 MHzMains & EUT Connections: 4 mm shrouded banana socketsRF Connector: 50 Ω BNC (Female)RF Input Voltage: 40 V (Max)Standards Met: IEC / EN 61000-4-6Voltage Division Factor: 9.5 dB +4 / -1Voltage Rating: 250 V AC / 350 V DC (Line to Ground)