CISPR 15 Test Equipment, Systems & Solutions
-
Teseq CDN M316 Coupling/Decoupling Network (CDN) CDN M3 Type
SKU: sku-224
Weight: 700 grams (1.5 LB.'s)Application/Test Type: 3 power lines, (L+N+PE), (2L+PE), (Optional L+L+L)Common Mode Impedance: 150 Ω +10/-20 ΩCurrent Rating: 10 Amps MaximumDecoupling of Common Mode Disturbance: Greater than 30 dBDimensions: 4.1 x 3 x 5 inches (10.5 x 7.5 x 12.5 cm)Frequency Range: 150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)Insertion Loss: Greater than 0.1 dBMains & EUT Connections: 4 mm, safety (Optional IEC 320 16A)RF Connector: BNC, 50 ΩRF Input Voltage: Less than 30 VStandards Met: IEC 61000-4-6, CISPR 16-1-2, CISPR 16-2-1 and CISPR 15Voltage Division Factor: 20 dB ±1.5 dBVoltage Rating: AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec -
Teseq CDN M210B Coupling Network with CEE 7/17 EUT Port & IEC 60320 C14 AE Port
SKU: sku-223
Weight: 3.3 Lbs (1.5 kg)Application/Test Type: switchable 2 or 3 power lines, (L+N or L+N+PE)Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 10 AmpsDecoupling of Common Mode Disturbance: 150 kHz: Greater than 30 dB 1.5 MHz: Greater than 60 dB 30 MHz: Greater than 40 dB 230 MHz: Greater than 20 dBDimensions: 3.9" x 3.9" x 9.5" (100 mm x 100 mm x 240 mm)Frequency Range: 150 kHz to 230 MHzInsertion Loss: Less than 0.1 dBMains & EUT Connections: AE Euro: IEC 60320 C14 EUT-socket 2lines: CEE 7/17;RF Connector: BNC 50 ΩRF Input Voltage: 30 Volts MaxStandards Met: IEC/EN 61000-4-6Voltage Division Factor: 150 kHz to 80 MHz: 9.5 dB ±1 dB 80 MHz to 230 MHz: 9.5 dB +3 dB / -2 dBVoltage Rating: AC max. voltage (line to ground): 250 V DC max. voltage (line to ground): 400 V; 3 kV DC, 2 sec$1,020.00 -
Teseq CDN M216 1kV CDN for CISPR 16-1-2, CISPR 16-2-1 and CISPR 15
SKU: sku-86
Weight: 700 grams (1.5 LB.'s)Application/Test Type: Emission measurement (CDNE) to measure disturbance voltages in the 30 to 300 MHz frequency range.Common Mode Impedance: 150 Ω +10/-20 ΩCurrent Rating: 10 Amps MaximumDecoupling of Common Mode Disturbance: Greater than 30 dBDimensions: 4.1 x 3 x 5 inches (10.5 x 7.5 x 12.5 cm)Frequency Range: 150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)Insertion Loss: Greater than 0.1 dBMains & EUT Connections: 4 mm, safetyRF Connector: BNC, 50 ΩRF Input Voltage: Less than 30 VStandards Met: IEC 61000-4-6, CISPR 16-1-2, CISPR 16-2-1 and CISPR 15Voltage Division Factor: 20 dB ±1.5 dBVoltage Rating: AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec -
Dressler S-25 Coupling/Decoupling Networks (CDN) 150 kHz-230 MHz
SKU: sku-397
Weight: 2.8 Lbs (1.27 kg)Current Rating: 1.5 AmpsFrequency Range: 150 kHz to 230 MHzRF Connector: BNCStandards Met: IEC/EN 61000-4-6Voltage Rating: 100 V -
Monthly Rental Teseq (Schaffner) CDN T002 Coupling Network for Unshielded Balanced Pairs
SKU: sku-318
Application/Test Type: EMC testing for unscreened data communication/telecom lines (Power over Ethernet, 1100BaseT4, 100Base VG-AnyLan, 1000BaseT, Token ring, ISDN, 10BaseT, 100BaseTX, ATM, FDDI, TP-PMDCurrent Rating: 1.5 Amps (3/5 Amp models available)Frequency Range: 150 kHz to 230 MHz (limited to 80 MHz on 3/5 Amp models)Mains & EUT Connections: Banana, XLR, RJ45, RJ11RF Connector: BNC, 50 ΩRF Input Voltage: 30 Volts MaxStandards Met: IEC 61000-4-6Voltage Rating: AC max. voltage (line to ground): 63 Volts DC max. voltage (line to ground): 100 Volts Test voltage: 200 VDC, 2 s$99.00